Resource Type

Journal Article 734

Conference Videos 41

Conference Topics 1

Year

2024 1

2023 57

2022 84

2021 57

2020 51

2019 46

2018 50

2017 49

2016 41

2015 65

2014 28

2013 41

2012 19

2011 25

2010 27

2009 27

2008 19

2007 24

2006 9

2005 9

open ︾

Keywords

maximum power point tracking (MPPT) 11

wind power 10

manufacturing power 8

renewable energy 8

nuclear power plant 7

optimization 6

power quality 6

automobile power 5

sustainable development 5

Active learning 4

MR damper 4

manufacturing 4

offshore wind power 4

power generation 4

smart grid 4

Artificial intelligence 3

Kalman filter 3

control 3

neural network 3

open ︾

Search scope:

排序: Display mode:

A simple digital control algorithm for three phase shunt active filter: simulation and experimentation

Subbaraman SRINATH, Chandan KUMAR, M. P. SELVAN

Frontiers in Energy 2014, Volume 8, Issue 1,   Pages 119-128 doi: 10.1007/s11708-013-0288-0

Abstract: control algorithm using digital signal processor (DSP) has been proposed and realized for a three phase shuntactive filter (SAF).The simulation and prototype construction of SAF is conducted to compensate the reactive power and harmonicssimulation results in reducing the total harmonic distortion (THD) of the source current and achieving unity power

Keywords: shunt active filter (SAF)     power quality     voltage source inverter (VSI)     digital signal processor (DSP)     total harmonic distortion (THD)     power factor improvement    

Power quality improvement using fuzzy logic controller for five-level shunt active power filter under

Amar BENAISSA,Boualaga RABHI,Ammar MOUSSI

Frontiers in Energy 2014, Volume 8, Issue 2,   Pages 212-220 doi: 10.1007/s11708-013-0284-4

Abstract: In this paper, a five-level inverter is used as a shunt active power filter (APF), taking advantagesIt is used to compensate reactive power and eliminate harmonics drawn from a thyristor rectifier feedingThe obtained results show that the proposed shunt APF controller has produced a sinusoidal supply current

Keywords: active power filter (APF)     harmonics isolator     distorted voltage conditions     self-tuning filters (STF)     fuzzy    

Rapid transaction to load variations of active filter supplied by PV system

M. BENADJA,S. SAAD,A. BELHAMRA

Frontiers in Energy 2014, Volume 8, Issue 3,   Pages 335-344 doi: 10.1007/s11708-014-0325-7

Abstract: and control of a photovoltaic (PV) system connected to the main supply through a Boost converter and shuntactive filter supplied by a PV system providing continuous supply of nonlinear load in variation.Validation of the developed model and control strategy is conducted using power system simulator Sim-PowerTo demonstrate the effectiveness of the shunt active filter to load changes, the method of instantaneouspower ( theory) is used to identify harmonic currents.

Keywords: solar panels     maximum power point tracking (MPPT)     DC/DC converter (Boost)     shunt active filter     instantaneouspower control     power quality     harmonics     imbalances     reactive energy    

Unified power quality conditioner based on a three-level NPC inverter using fuzzy control techniques

Salim CHENNAI,M-T BENCHOUIA

Frontiers in Energy 2014, Volume 8, Issue 2,   Pages 221-239 doi: 10.1007/s11708-014-0317-7

Abstract: This paper presents a novel and efficient control scheme for unified power quality conditioner (UPQC)It is designed by the integration of series and shunt active filters (AFs) sharing a common DC bus capacitorThe synchronous reference frame (SRF) theory is used to get the reference signals for shunt active powerfilters (APFs) and the power reactive theory (p-q theory) for series APFs.The shunt and series APF reference signals derived from the control algorithm and sensed signals are

Keywords: three-level neutral point clamped (NPC) inverter     unified power quality conditioner (UPQC)     current harmonicsmitigation     fuzzy logic controller     voltage disturbance compensation     shunt active filter     series activefilter     power quality energy improvement    

A multi-modular shunt active power filter system and its novel fault-tolerant strategy based on split-phase None

Qun-wei XU, Jin-xiang ZHAN, Long XIAO, Guo-zhu CHEN

Frontiers of Information Technology & Electronic Engineering 2018, Volume 19, Issue 9,   Pages 1166-1179 doi: 10.1631/FITEE.1601296

Abstract:

We first present a new multi-modular shunt active power filter system suitable for large-capacityresulting in a continuous operation of the faulted module and optimization of the remaining usable power

Keywords: Shunt active power filter     Fault-tolerant topology     Split-phase control     Bus communication    

Robust switched fractional controller for performance improvement of single phase active power filter

H. AFGHOUL,F. KRIM,D. CHIKOUCHE,A. BEDDAR

Frontiers in Energy 2016, Volume 10, Issue 2,   Pages 203-212 doi: 10.1007/s11708-015-0381-7

Abstract: A novel controller is proposed to regulate the DC-link voltage of a single phase active power filterThus, the purpose of this paper is to switch to the PI controller in steady-state to obtain the best power

Keywords: calculus (FC)     total harmonic distortion (THD)     Oustaloup continuous approximation (OCA)     single phase activepower filter (SPAPF)    

A New Real-time Detecting Method for Harmonic Current Based on Iterative Algorithm in Active Power Filter

Li Zicheng,Sun Yukun

Strategic Study of CAE 2006, Volume 8, Issue 1,   Pages 46-50

Abstract: current analysis, a new real-time detecting method for harmonic current based on iterative algorithm in activepower filter is proposed, It has the characteristics of very little calculating work, nice real time

Keywords: active power filter     harmonics current     active current     reactive current    

Current Source Active Power Filter Control UsingNeural Network Technologies

Wang Ping,Zhang Ke, Xu Huijun

Strategic Study of CAE 2007, Volume 9, Issue 1,   Pages 40-43

Abstract:

In this paper,the application of neural network to power converter controlneural network can learn the control rules by itself and can replace the real hysteresis comparator in power

Keywords: source filter     neural network     hysteresis comparator    

Performance investigation of artificial intelligence based controller for three phase four leg shuntactive filter

J. JAYACHANDRAN,R. MURALI SACHITHANANDAM

Frontiers in Energy 2015, Volume 9, Issue 4,   Pages 446-460 doi: 10.1007/s11708-015-0378-2

Abstract: In this paper, the choice of power quality compensator is a DSTATCOM which constitutes a three phase

Keywords: neural network     DSTATCOM     neutral current mitigation     total harmonic distortion (THD)     three phase four wire distribution system     unbalanced and/or distorted source    

UPFC setting to avoid active power flow loop considering wind power uncertainty

Shenghu LI, Ting WANG

Frontiers in Energy 2023, Volume 17, Issue 1,   Pages 165-175 doi: 10.1007/s11708-020-0686-z

Abstract: The active power loop flow (APLF) may be caused by impropriate network configuration, impropriate parameterThe power flow controllers, e.g., the unified power flow controller (UPFC), may be the reason and theapproaching to the critical existing condition, the integrated power flow needs less iterations andBesides, with wind power fluctuation, the interval power flow (IPF) is introduced into the integratedpower flow, and solved with the affine Krawcyzk iteration to make sure that the range of active power

Keywords: active power loop flow (APLF)     unified power flow controller (UPFC)     wind power uncertainty     interval power    

Performance of PI controller for control of active and reactive power in DFIG operating in a grid-connected

Azzouz TAMAARAT,Abdelhamid BENAKCHA

Frontiers in Energy 2014, Volume 8, Issue 3,   Pages 371-378 doi: 10.1007/s11708-014-0318-6

Abstract: The objective of this work is to present the modeling and control strategy of a grid connected wind powerIt will introduce the vector control, which makes it possible to control independently the active andreactive power exchanged between the stator of the generator and the grid, based on vector control conceptIt is also interesting to play on the quality of electric power by controlling the reactive power exchangedwith the grid, which will facilitate making a local correction of power factor.

Keywords: wind power     doubly fed induction generator (DFIG)     vector control     active power     reactive power     maximum power    

H control in the frequency domain for a semi-active floor isolation system

Yundong SHI, Tracy C BECKER, Masahiro KURATA, Masayoshi NAKASHIMA

Frontiers of Structural and Civil Engineering 2013, Volume 7, Issue 3,   Pages 264-275 doi: 10.1007/s11709-013-0214-x

Abstract: Semi-active control with an control was adopted for the floor isolation system and a new input shapingfilter was developed to account for the input motion characteristics and enhance the effectiveness ofA series of shake table tests for a semi-active floor isolation system using rolling pendulum isolators

Keywords: semi-active     floor isolation     H control     MR damper     shaping filter     shaking table    

Vibration control efficiency of piezoelectric shunt damping system

Dan WU, Zhichun YANG, Hao SUN,

Frontiers of Mechanical Engineering 2009, Volume 4, Issue 4,   Pages 441-446 doi: 10.1007/s11465-009-0055-4

Abstract: The piezoelectric shunt damping technique based on the direct piezoelectric effect has been known asWhen applying the piezoelectric shunt damping technique to passively control structural vibration, theIn this paper, the concept of vibration control efficiency of a piezoelectric shunt damping system isplates, respectively, and vibration control experiments are conducted for these plates using the R-L shuntIt comes to a conclusion that the vibration control efficiency of the piezoelectric shunt damping system

Keywords: piezoelectric shunt     vibration control efficiency     clamped plate     generalized electromechanical coupling    

Active Support of Power System to Energy Transition Editorial

Yusheng Xue

Engineering 2021, Volume 7, Issue 8,   Pages 1035-1036 doi: 10.1016/j.eng.2021.07.002

Active-reactive power scheduling of integrated electricity-gas network with multi-microgrids

Frontiers in Energy 2023, Volume 17, Issue 2,   Pages 251-265 doi: 10.1007/s11708-022-0857-1

Abstract: development of the integrated electricity-gas network (IEGN) and strengthening the interaction between the active-reactivepower flow in the power distribution network (PDN) and the natural gas flow in the gas distributionThis paper proposes a day-ahead active-reactive power scheduling model for the IEGN with multi-microgrids) is considered to optimize the active and reactive power capabilities of the inverters of distributedFurther, a second-order cone (SOC) relaxation technology is utilized to transform the proposed active-reactive

Keywords: combined cooling     heating     and power (CCHP)     integrated energy systems (IES)     natural gas     power distribution    

Title Author Date Type Operation

A simple digital control algorithm for three phase shunt active filter: simulation and experimentation

Subbaraman SRINATH, Chandan KUMAR, M. P. SELVAN

Journal Article

Power quality improvement using fuzzy logic controller for five-level shunt active power filter under

Amar BENAISSA,Boualaga RABHI,Ammar MOUSSI

Journal Article

Rapid transaction to load variations of active filter supplied by PV system

M. BENADJA,S. SAAD,A. BELHAMRA

Journal Article

Unified power quality conditioner based on a three-level NPC inverter using fuzzy control techniques

Salim CHENNAI,M-T BENCHOUIA

Journal Article

A multi-modular shunt active power filter system and its novel fault-tolerant strategy based on split-phase

Qun-wei XU, Jin-xiang ZHAN, Long XIAO, Guo-zhu CHEN

Journal Article

Robust switched fractional controller for performance improvement of single phase active power filter

H. AFGHOUL,F. KRIM,D. CHIKOUCHE,A. BEDDAR

Journal Article

A New Real-time Detecting Method for Harmonic Current Based on Iterative Algorithm in Active Power Filter

Li Zicheng,Sun Yukun

Journal Article

Current Source Active Power Filter Control UsingNeural Network Technologies

Wang Ping,Zhang Ke, Xu Huijun

Journal Article

Performance investigation of artificial intelligence based controller for three phase four leg shuntactive filter

J. JAYACHANDRAN,R. MURALI SACHITHANANDAM

Journal Article

UPFC setting to avoid active power flow loop considering wind power uncertainty

Shenghu LI, Ting WANG

Journal Article

Performance of PI controller for control of active and reactive power in DFIG operating in a grid-connected

Azzouz TAMAARAT,Abdelhamid BENAKCHA

Journal Article

H control in the frequency domain for a semi-active floor isolation system

Yundong SHI, Tracy C BECKER, Masahiro KURATA, Masayoshi NAKASHIMA

Journal Article

Vibration control efficiency of piezoelectric shunt damping system

Dan WU, Zhichun YANG, Hao SUN,

Journal Article

Active Support of Power System to Energy Transition

Yusheng Xue

Journal Article

Active-reactive power scheduling of integrated electricity-gas network with multi-microgrids

Journal Article